Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Shiny Surfaces and Tight Workspaces: How to Get a Measurable Image Without GlareMoving Parts Come Out Sharp When All Pixels Are Exposed at the Same TimeCrack width in tenths of a millimeter: why you measure instead of guessingWith 15 Centimeters of Clearance to the Circuit Board, There Is Room for Both the Soldering Iron and Your Line of SightShiny metal surfaces can be measured once the reflections disappear and the entire surface is in focusReflections on the metal surface hide the scratch: how to see it with polarized light and a measurement functionInspect the solder joint on a screen right at the workstation, without a computer and without getting too closeAtt se in i röret i stället för att gissa: så sparar en inspektionskamera dagar av felsökningMeasure the scratch, edge or hole on site before the part is sent to the measuring roomMeasure under the microscope instead of next to it: get documentable measurements without losing your workspaceVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Shiny Surfaces and Tight Workspaces: How to Get a Measurable Image Without GlareMoving Parts Come Out Sharp When All Pixels Are Exposed at the Same TimeCrack width in tenths of a millimeter: why you measure instead of guessingWith 15 Centimeters of Clearance to the Circuit Board, There Is Room for Both the Soldering Iron and Your Line of SightShiny metal surfaces can be measured once the reflections disappear and the entire surface is in focusReflections on the metal surface hide the scratch: how to see it with polarized light and a measurement functionInspect the solder joint on a screen right at the workstation, without a computer and without getting too closeAtt se in i röret i stället för att gissa: så sparar en inspektionskamera dagar av felsökningMeasure the scratch, edge or hole on site before the part is sent to the measuring roomMeasure under the microscope instead of next to it: get documentable measurements without losing your workspace

Coaxially illuminated measuring microscope 100x — on a chrome-plated surface, side light shines in the wrong direction

Published August 20, 2026 at 07:37

You need to inspect a scratch on a chrome-plated part. The microscope is in focus, the magnification is more than sufficient — yet looking through the eyepiece, you can barely see a thing. The surface is either blindingly white or nearly pitch black, depending on how you angle the component, and the feature you are looking for is lost in both positions. The issue is not that the optics are inadequate. It is that the illumination is coming from the wrong direction.

Peak Lupe 2064-CIL-LED portabelt mätmikroskop 100x med koaxial LED-belysning och aluminiumbas

What it is

The Peak Lupe 2064-CIL-LED is a portable measuring microscope featuring both coaxial and oblique (side) illumination, shown here with 100x magnification (the series is available from 40x to 300x). A glass reticle scale is built in, allowing the instrument to measure length, thickness, and height directly through the eyepiece. The illumination uses LEDs powered by a battery compartment for two AA cells and includes a potentiometer for brightness control. The base is made of aluminium, and focusing is adjusted smoothly via a rack-and-pinion system. This model replaces the older 2054-CIL with significantly extended battery life; the optics remain the proven design shared with the 2034 and 2054 series.

The problem it solves

On a matte surface, light scatters in all directions, so the angle of incidence makes little difference. On a glossy, specular surface, the exact opposite happens: light reflects like a mirror. If it enters at an angle, it reflects away at an angle — clear past the objective lens — rendering the surface dark. If a direct glare hits the right angle, the surface becomes blindingly bright. In neither case can you clearly see what you set out to inspect.

Coaxial illumination solves this by directing light through the lens, along the exact same optical axis as your line of sight. A flat, polished surface reflects the light straight back into the objective, appearing uniformly bright — while scratches, voids, chipped edges, and other imperfections deflect the light away, standing out as crisp, dark details against a bright background. Effective inspection only becomes possible when the light travels the correct path.

Retaining the oblique side illumination is just as vital, as it performs the complementary function: casting shadows to accentuate topography and surface texture. A classic example is the inspection of halftone dots in printing, where you need to evaluate dot geometry and edge definition. Having both lighting methods in a single instrument means you can simply switch the illumination technique rather than tilting and turning the workpiece in the hope of catching a usable reflection.

Furthermore, because the reticle scale is located directly in the eyepiece, the exact image you evaluate is the one you measure — eliminating the need to move the component to a benchtop system just to quantify the defect you have identified.

Three typical use cases

  • Surface inspection on specular components: Chrome-plated, polished, and ground surfaces where scratches, pinholes, and coating defects must be evaluated and measured.
  • Printing and graphic arts quality control: Halftone dots, register accuracy, and edge sharpness — utilizing side illumination to reveal dot structure.
  • Inspection of rollers and large surface areas: Where the microscope, combined with an MST stand, is placed directly onto the workpiece instead of the other way around — enabling on-site measurement without disassembly.

Why it pays off

The hidden cost of improper illumination is the defect that goes undetected. A surface flaw that cannot be visualised cannot be documented, and a part that simply ”looked fine under the microscope” passes inspection — until the customer spots the scratch in broad daylight. The limiting factor was not the optical resolution of the instrument, but whether the defect could be rendered with sufficient contrast.

Then there is the advantage of portability. A stationary bench microscope requires the workpiece to be transported to the inspection room. For rollers, long extrusions, or fully assembled machinery, that means extensive teardown — or skipping the inspection altogether. A battery-powered instrument that sits directly on the workpiece brings the inspection to wherever it is needed, ensuring quality checks are actually performed. Upgrading to LED illumination also ensures that two standard AA batteries last substantially longer, an advantage that might sound minor until an instrument goes dark mid-inspection.

Read more about the Peak Lupe 2064-CIL-LED measuring microscope 100x →

More news